Woke to house bank around 11.8V after fridge ran overnight at the dock. Resting voltage midday is ~12.4V with shore charger idle. No new loads except the fridge compressor we installed last month.
Thread
You · Alex Rivera
Sep 28, 2026 · 8:14 AM PT
Agent · Sailor Cruiser Tech
Got it — Dark Horse, 12V AGM house bank, new fridge. Guided troubleshooting and repair solutions start with measurement, not parts swapping.
- Note resting voltage after 30+ minutes with fridge off and charger disconnected.
- Clamp fridge amp draw while running (compressor on vs off).
- Confirm shore charger bulk/absorb settings match AGM (typically ~14.4 / 13.6).
Reply with those three numbers and we will narrow next steps.
Sep 28, 2026 · 9:02 AM PT
You · Alex Rivera
Resting 12.55V. Fridge peaks ~6.2A then settles ~4.8A. Charger absorb set to 14.6V — may be a bit high for these AGMs?
Sep 29, 2026 · 7:40 AM PT
Agent · Sailor Cruiser Tech
Amps look plausible for that box. Overnight sag with ~5A continuous suggests either a smaller usable bank than labeled, a high phantom load, or the charger not topping off before you go to sleep.
- Lower absorb toward manufacturer AGM recommendation (often 14.2–14.4).
- Leave fridge on, kill other DC breakers overnight, re-check morning voltage.
- If still sagging hard, load-test / capacity-check the bank — age and heat kill AGM capacity quietly.
Sep 29, 2026 · 10:18 AM PT